Key Features

Speech intelligibility measurements
STIPA and full STI (fast method)
Built-in STI/STIPA signal generator
Calculates average STI from multiple measurements
Data stored in human-readable JSON files for later review
Designed to meet or exceed the requirements of IEC standard 60268-16, Edition 5.0 (2020-09)

Specifications

  • Input: 1 channel at a time, selected from any available input, output, or virtual output channels
  • Test Type: STIPA, STI Fast
  • STIPA Measurement Durations (seconds): 15, 18, 21, 25
  • STI Fast Measurement Durations (seconds): 8, 12, 15, 18
  • Auditory Masking Correction: Enable/Disable
  • Speech Reception Threshold Correction: Enable/Disable
  • Expected Test Signal Modulation Depth: 0.55
Added Noise
  • Calculate STI With Added Noise: Enable/Disable
  • Supported Octave Bands (Hz): 125, 250, 500, 1000, 2000, 4000, 8000
  • Added Noise Level (dB): User-defined
  • Noise Level Units: dB SPL, dBV, dBFS
Built-in Test Signal Generator
  • Enable/Disable
  • Signal Type: STIPA or related STI signal with alternate modulation frequencies per octave band
  • Presend (seconds): User-definable value greater than or equal to zero
  • Level: specified in dBFS where 0 dBFS is the maximum (full scale) output amplitude
  • Output Channel: Selected from any available output or virtual output channels
  • Modulation Depth: 0.55
Display
  • Display Type: Octave Band Levels, MTF (Modulation Transfer Function Matrix), TI (Transmission Index Matrix)
  • Supported Octave Bands: 125, 250, 500, 1000, 2000, 4000, 8000
  • Autoscale Off, Auto
  • dB Level Scale (dB/Div) 0.01, 0.02, 0.03, 0.04, 0.05, 0.06, 0.08, 0.09, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 0.9, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 9.0, 10.0, 12.0, 15.0, 16.0, 18.0, 20.0, 24.0, 25.0, 27.0, 30.0
Data Export
  • Test data is automatically saved each time a measurement reaches the user-selected duration.
  • Data File Format: JSON
Data Import
  • A single test file may be loaded at a time.
  • Data File Format: JSON
Additional Specifications
Modulation depth
  • STIPA and STI (Fast) test signals employ a modulation depth of 0.55. A perfect STI of 1.0 requires that the received signal also exhibit a modulation depth of 0.55, which would result in a modulation transfer ratio (m-value) of 1.0.
  • EC 60268 requires that the absolute value of any error in m-value determination not exceed 0.05 and that all m-value errors not yield an error in the overall STI value greater than 0.01.
  • In our testing of STIPA measurements made with SignalScope, using standard verification signals available from www.stipa.info, we observed differences between measured m-values and expected m-values of no greater than 0.011 across all frequency bands and modulation frequencies.
  • Our tests were performed by analyzing the digital signals directly--no analog circuitry was included in the signal path. The STIPA measurement ran with the standard's recommended averaging time of 18 seconds.
Crosstalk between octave-band filters
  • Poor design of the octave-band filters can lead to crosstalk which effectively increases the noise level in adjacent frequency bands, causing the m-values to be underestimated. A STIPA measurement device can be tested for this using the standard verification signals avilable from www.stipa.info.
  • When testing filter performance using standard verification signals, the m-value in each octave band can be observed with a high-amplitude signal present in an adjacent octave band. IEC 60268 requires that the m-value in the observed band be at least 0.5 (+/-0.05).
  • In our testing with SignalScope, the minimum m-value in any observed band with any modulation frequency across all test cases was 0.607.
  • Our tests were performed by analyzing the digital signals directly--no analog circuitry was included in the signal path. The STIPA measurement ran with the standard's recommended averaging time of 18 seconds.
Supported octave frequency bands and modulation frequencies
  • STIPA
    Octave Band, Hz 125 250 500 1k 2k 4k 8k
    Mod Freq (Fm) 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5
  • Full STI (Fast)
    Octave Band, Hz 125 250 500 1k 2k 4k 8k
    Fm, Meas. Part 1 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5
    Fm, Meas. Part 2 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5 1.60 & 8.00
    Fm, Meas. Part 3 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5 1.60 & 8.00 1.00 & 5.00
    Fm, Meas. Part 4 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15
    Fm, Meas. Part 5 1.25 & 6.25 0.80 & 4.00 2.50 & 12.5 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0
    Fm, Meas. Part 6 0.80 & 4.00 2.50 & 12.5 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25
    Fm, Meas. Part 7 2.50 & 12.5 1.60 & 8.00 1.00 & 5.00 0.63 & 3.15 2.00 & 10.0 1.25 & 6.25 0.80 & 4.00